Section 6.08.060 Alarm system requirements.

    A.    No person shall install, use, operate, maintain or monitor an alarm or alarm system which does not meet or exceed applicable federal and state standards and regulations.
    B.    No person shall install, use, operate, maintain or monitor an alarm or alarm system that, upon activation,
emits a sound similar to sirens used on official emergency vehicles or for civil defense purposes.
    C.    No person shall install, use, operate, maintain or monitor an alarm or alarm system which emits an audible alarm sound and which does not have an approved automatic shut-off mechanism that will shut off the audible alarm sound within a maximum time of fifteen (15) minutes from the time it is activated.
    D.    No alarm or alarm system shall be installed, used, operated, maintained or monitored without an approved functioning standby backup power supply which will automatically assure its operation in the event of an interruption in the primary power source. The transfer of power from the primary source to the standby backup source, or vice versa, must occur in a manner that does not activate the alarm. (Ord. 2005-35 § 2 (part))
6.08.060