Chapter 6.60 NOISE
Section 6.60.040 Exterior noise level standards.
A. It is unlawful for any person at
any location within the unincorporated area of the county
to create any noise or to allow the creation of any noise on property owned, leased, occupied or
otherwise controlled by such person which causes the exterior noise level when measured at any
single- or multiple-family residential, school, hospital, church, public library or commercial
properties situated in either the incorporated or unincorporated area to exceed the noise level
standards as set forth in Table 6.60.040A or Table 6.60.040B following:
Table 6.60.040A
Receiving Land Use Single- or Multiple-Family Residential,
School, Hospital, Church or Public Library Properties
Noise Level Standards, dB(A)
|
Category
|
Cumulative
Number of
Minutes in
any one
hour time
period
|
Daytime
7 a.m. to
10 p.m.
|
Nighttime
10 p.m. to
7 a.m.
|
|
1
|
30
|
50
|
45
|
|
2
|
15
|
55
|
50
|
|
3
|
5
|
60
|
55
|
|
4
|
1
|
65
|
60
|
|
5
|
0
|
70
|
65
|
Table 6.60.040B
Receiving Land Use Commercial Properties
Noise Level Standards, dB(A)
|
Category
|
Cumulative
Number of
Minutes in
any one
hour time
period
|
Daytime
7 a.m. to
10 p.m.
|
Nighttime
10 p.m. to
7 a.m.
|
|
1
|
30
|
65
|
60
|
|
2
|
15
|
70
|
65
|
|
3
|
5
|
75
|
70
|
|
4
|
1
|
80
|
75
|
|
5
|
0
|
85
|
80
|
B. In the event the measured ambient
noise level exceeds the applicable noise level standard
in any category above, the applicable standard shall be adjusted so as to equal said ambient noise
level.
C. Each of the noise level standards
specified in Tables 6.60.040A and B shall be reduced by
five dB(A) for simple tone noises, noises consisting primarily of speech or music or for recurring
impulsive noises.
D. If the intruding noise source is
continuous and cannot reasonably be discontinued or
stopped for a time period whereby the ambient noise level can be measured, the noise level
measured while the source is in operation shall be compared directly to the applicable noise level
standards in Table 6.60.040A and Table 6.60.040B.
E. Notwithstanding the noise level
standards set forth in this section, the noise level standard
applicable to the emission of sound from transformers, regulators, or associated equipment in
electrical substations shall be 60 dB(A). (Prior gen. code §§ 3-107.401 3-107.405)